On Monday, Nov. 23, Norway’s Institute of Marine Research (HI) advised national authorities for the first time to have hospitals treat or disinfect their wastewater locally, after Bergen sampling found multiresistant E. coli and Klebsiella in raw hospital sewage and in treated effluent leaving the plant for the fjord. HI describes it as its first advice on wastewater treatment.
The question matters well beyond Norway, because hospital wastewater and antibiotic resistance meet in a plumbing arrangement most countries share: researchers piloting ozone treatment at Uppsala University Hospital wrote that a vast majority of hospitals do not treat their sewage and send it to municipal plants as is. Norway is a hard test case for the argument: a European Commission summary describes the country as having comparatively low antibiotic use, low resistance in clinics and very limited use of carbapenems, last-resort drugs.
The advice went to the Ministry of Trade, Industry and Fisheries and to four agencies: the Norwegian Directorate of Health, the Norwegian Environment Agency, the Directorate of Fisheries and the Norwegian Food Safety Authority, according to HI’s news page. It appears as HI report 2026-80 by Nachiket Marathe, Manish Prakash Victor, Livar Frøyland and Monica Sanden, and is backed by a companion knowledge synthesis, report 2026-82. HI is an agency under the Ministry of Trade, Industry and Fisheries whose main task is to advise authorities, so the report is advice, not a regulation.
The advice leans on HI’s Res-Marine project, funded by the Research Council of Norway and led by Marathe. Between 2020 and 2023 the team sampled raw and treated sewage at five Bergen treatment plants. In a December 2024 write-up, HI reported 1,580 bacteria resistant to at least one antibiotic. It also reported that carbapenem-resistant E. coli turned up only at the plant that receives the city’s hospital sewage, in both raw and treated water.
A narrower study then took 24-hour composite samples of raw and treated sewage at Bergen’s second-largest plant, which serves about 130,000 residents plus two hospitals, and from the sewer line of Haukeland University Hospital. HI’s page calls it the Laksevåg plant. The European Commission summary and the preprint name the plant Holen, and the Commission describes it as Norway’s second-largest. The peer-reviewed results appeared in Ecotoxicology and Environmental Safety (Victor et al., 2025), according to the Commission’s summary of the paper.
According to HI and the Commission’s summary of the paper:
The synthesis report adds specific mechanisms. It describes OXA-244-producing E. coli ST38, a carbapenemase producer, only in untreated and treated effluent from the plant that receives hospital sewage, and it lists the carbapenemase genes NDM-6 and VIM-1 among clinically important genes found in E. coli from Bergen wastewater. In the earlier medRxiv preprint, which had not been peer reviewed, sequencing of 36 strains turned up the carbapenemases NDM-5 and KPC-3, three strains each, and all 66 E. coli isolates tested were multidrug-resistant.
The gene counts differ between documents, though the match is traceable. The synthesis report cites 1,205 genes, 365 of them new, which match the preprint’s 1,205 assembled gene sequences, 365 of them below 90% identity to known genes. The peer-reviewed paper, as summarized by the Commission, reports 1,130 and 349, and the documents do not explain why its counts are lower. The preprint sampled on two dates, Feb. 7 and April 12, 2023.
The Commission summary notes that Norway does not treat hospital effluent on site, as many other countries do. HI’s report asks for on-site treatment of hospital wastewater to remove clinically important pathogens and resistance before the water reaches municipal plants, and, over the longer term, tertiary treatment upgrades at municipal plants. It also calls for strengthened marine and coastal monitoring of antimicrobial resistance (AMR) under a One Health approach, which links human, animal and environmental health.
HI says hospital sewage is especially important because it contains disease-causing bacteria under selection pressure. Marathe’s argument for acting is that everything released into the sea “eventually comes back to us,” through swimming or seafood. Research director Monica Sanden says Norway can get ahead of a global problem, and HI director Nils Gunnar Kvamstø says the total burden on the sea has to be taken into account.
HI lays out three scenarios. In the first, current practice continues, hospital sewage goes untreated to municipal plants, and resistance, which HI says has risen steadily over 20 years while remaining relatively low, keeps spreading. In the second, climate change adds warmer seas that favor gene transfer between bacteria. In the third, which HI recommends, local treatment or disinfection breaks the route. The scenarios are qualitative: the synthesis report presents no quantified projections.
HI’s report names no specific treatment technology, such as UV, ozonation or membranes, and gives no performance data on how well on-site or tertiary treatment would cut resistance. It also leaves cost and feasibility unaddressed. Field evidence from elsewhere is mixed.
Some hospitals already do it. A university hospital in Copenhagen runs a full-scale membrane bioreactor and ozonation plant, according to the Uppsala paper. A 2019 study of two Dutch cities found that in the one city where hospital wastewater was treated on site with membrane bioreactor treatment, ozonation, activated carbon and UV, hospital-related resistance genes and antibiotics dropped in the receiving municipal plant. The abstract says technologies hit different pollutants to different degrees, so combining them in sequence worked better.
The Uppsala result went the other way for the one technology it tested. Swedish researchers piloted ozonation on untreated sewage at the 1,000-bed Uppsala University Hospital. They found no significant drop in resistant, ESBL-producing Enterobacteriaceae. Antibiotic levels fell by a mean of 41% at low flow but only 6% at high flow. The system clogged quickly and ozone leaked, and the pilot ran as planned for only about two months under a technician’s supervision. The authors judged the setup unsuitable for full-scale use in their hospital.
The practical point for Norway: choosing among these options, and proving they cut resistance genes rather than just drug residues, is an engineering task HI’s advice leaves to others.
A Nature Communications study from Gothenburg, released Oct. 29, found that sewage from all ten hospitals tested, in eight Swedish cities, gave resistant E. coli a growth advantage that municipal plant sewage did not. Fluoroquinolones and penicillin-like antibiotics were the main drivers, with ciprofloxacin identified as a key one. Joakim Larsson, who leads the Centre for Antibiotic Resistance Research there, said hospital sewage systems are a priority site for targeted interventions. His team says advanced treatment at municipal plants can limit further spread of antibiotics but cannot reverse resistance that already developed in hospital sewage, and it is developing a targeted treatment method.
The university’s release describes laboratory selection tests using an engineered resistant strain and reports no infections in people.
HI’s focus on hospitals is not uncontested in the Norwegian literature. A 2020 doctoral thesis by Erik Paulshus at the Norwegian University of Life Sciences, reported in Norsk Veterinærtidsskrift, sampled a hospital outlet, a residential pumping station and the inflow to Norway’s largest treatment plant. The hospital sewage came out worst, but the residential station showed higher levels of resistant bacteria than the plant inflow, and Paulshus concluded the situation is more complex than assumed.
Cost caution is also old. In 2015, Henning Sørum, a researcher at the Norwegian University of Life Sciences, told Teknisk Ukeblad he understood why hospitals had hesitated to build their own treatment plants while the research was still weak, and warned that overspending on a danger later shown to be overstated could make future resistance measures harder to fund.
The recommendation is not a finding of harm: HI’s report does not quantify health risk, and its documents are candid about other gaps.
HI’s report says the EU’s 2024 urban wastewater directive (2024/3019) will require AMR monitoring in sewer systems and receiving waters from the end of 2027. The European Environment Agency says Member States must start reporting by December 2030. The two dates come from different documents, which do not reconcile them. The directive’s monitoring covers large agglomerations of at least 100,000 person equivalents, according to a January Eurosurveillance perspective. Climate and Environment Minister Andreas Bjelland Eriksen told a Storting committee on March 19 that the government wants to incorporate the revised wastewater directive into the EEA agreement and Norwegian law.
HI has put hospital wastewater antibiotic resistance on Norway’s policy table with an ask that would fall on hospital operators: treat or disinfect on site. The evidence that resistance genes pass through Bergen’s treatment plant is specific and sourced. The evidence that any particular on-site system would stop them is not yet in HI’s documents, and studies from the Netherlands and Sweden point different ways. The question for Oslo is whether to act now, while Norway’s clinical numbers are good, or wait for stronger evidence on how much treated sewage contributes to human infections. HI’s answer is to act early and to start measuring. A reader watching this debate, in Norway or in any country where hospitals send untreated sewage to municipal plants, should look for three things next: a named technology, measured resistance-gene removal, and a cost estimate.
Often not. Norway does not treat hospital effluent on site, according to the European Commission summary, and the Uppsala paper says most hospitals send sewage to municipal plants untreated. A university hospital in Copenhagen is one example of on-site treatment, and a Dutch city with advanced treatment is another.
Not completely. HI says treatment does not remove resistance genes carried in hospital sewage, so they reach the sea. In Bergen, 54 genes were shared between hospital sewage and treated effluent.
HI lists bathing and seafood as exposure routes, but the synthesis report states that detecting resistance in the environment does not itself show transmission to humans. Resistance levels in patients and animals remain relatively low in Norway, according to the report.
HI names none. Options with published results include membrane bioreactors, ozonation, activated carbon and UV, but outcomes differ: one Dutch site cut hospital-related resistance genes downstream, while an Uppsala ozone pilot did not reduce resistant Enterobacteriaceae.